Abstract
Introduction
Phantom limb pain (PLP) is a common and debilitating condition affecting a large proportion of amputees and is associated with maladaptive cortical plasticity. Neuroprosthetic interventions may restore sensorimotor integration and thereby reduce PLP. This systematic review aimed to evaluate whether different neuroprosthetic approaches reduce PLP and to identify which modalities demonstrate the greatest pain reduction.
Methods
This review was conducted in accordance with PRISMA guidelines. Eligible studies investigated upper-limb amputees receiving neuroprosthetic interventions, specifically Transverse Intrafascicular Multichannel Electrodes (TIME), virtual augmented reality (VAR) or myoelectric prostheses. Phantom limb pain was assessed using the Visual Analogue Scale (VAS) before and after the intervention with specialist training.
Results
Seven observational studies comprising 32 participants met the inclusion criteria. Overall, 87.5% of participants demonstrated a reduction in VAS scores following intervention. All included studies reported a mean decrease in PLP following neuroprosthetic use, with the largest reductions observed in studies involving TIME electrodes and VAR-based interventions. However, effect sizes varied considerably across studies.
Conclusion
The findings suggest that neuroprosthetic interventions may be associated with reductions in phantom limb pain; however, the evidence remains preliminary. Small sample sizes, study heterogeneity, and reliance on observational designs limit the strength of conclusions. Further high-quality, longitudinal studies are required to establish efficacy and inform clinical implementation.
Introduction
Phantom limb pain (PLP) is characterised as perception of pain or discomfort in a limb that no longer exist which is experienced in up to 80% of amputees [3]. This is caused due to a structural change in the brain, resulting in reorganisation of the somatosensory cortex, referred to as cortical plasticity [1]. Neuroprosthetics are devices that are used for amputee patients that involve an electrode interface within the central nervous system (CNS) or peripheral nervous system (PNS) also known as a neural interface, which restores sensory and motor function via stimulation of the proximal nerves and muscles [8]. A completely functional neuroprosthesis encompasses two main functions: direct motor output and sensory input; this mimics the bidirectional controlled feedback loop of an intact limb [9]. There are various types of neuroprosthesis, this systematic review is focussed on myoelectric prosthesis; Transverse Intrafascicular Multichannel Electrodes (TIME) and Virtual Augmented Reality (VAR).
The rationale behind this systematic review is to compare the forms of prosthetic devices and their function to reduce PLP.
Methods
This systematic review was accomplished via the Preferred Reporting Items for Systematic Review and Meta Analyses [10].

Observational (Cohort, Case-Control, Cross Sectional) studies were used as the patient was needed to be informed of the procedure and the results from the intervention were dependent on patient effort and dedication to reducing phantom limb pain.
The observational studies provided insight to the relationship between these neural interfaces and phantom limb pain reduction as well as showing improvement in mobility.
The participant criterion included upper limb amputees over the age of 18 also limiting the research to one aspect of the body which creates more comparable results. Numerous studies on phantom limb pain were based on veterans, which were excluded from this study due to the confounding factors that these participants had, such as PTSD, major physical trauma elsewhere, numerous amputations [11] which is not applicable to all amputees and therefore there should be a separate study on the impacts of neuroprosthesis on veterans PLP.
| Inclusion Criteria | |
| Type of study | Interventional (Randomised Controlled Trials); Observational (Cohort, Case-Control, Cross Sectional) |
| Participant | Adult (18+); upper limb amputee |
| Intervention | Neuroprosthetics including TIME, VRE, Myoeclectric Prosthesis |
| Outcome Measures | Phantom Limb Pain effects recorded from the Visual Analogue Scale (VAS) |
| Exclusion Criteria | |
| Type of Study | Systematic Reviews; Reviews; Demographic Surveys |
| Participant | Animal; Lower Limb Amputee; Not 18+ |
| Intervention | TENS; TMR; Mirror; Not a neuroprosthetic device |
| Outcome Measures | Not linked to Phantom Limb Pain |
| Others | Cannot access full text |
Interventions involve Transverse Intrafascicular Multichannel Electrodes (TIME), Virtual Augmented Reality (VAR) and Myoelectric devices. TIME, VAR, and myoelectric devices were included as they are therapies used to improve the function of the neuroprosthetic and can easily quantify phantom limb pain pre and post intervention.
Targeted Muscle Reinnervation (TMR) and Transcutaneous Electrical Nerve Stimulation (TENS) involves reinnervating the paralysed muscle so that its original function is restored, which does reduce phantom limb pain, however neuroprosthetics are not used as the patient has not had their limb amputated. Mirror therapy is used predominantly after a patient has had a stroke and can no longer move their limb [12].
Transverse Intrafascicular Multichannel Electrode (TIME)
(Studies 1 [1]), 2 [2], and 5 [5]). These are implanted in the peripheral nerve tissue within the epineurium which is located around the nerve bundles, allowing the electrode to access the nerve fascicles within the nerve trunk without penetrating the perineurium. The transverse design of the electrode enables it to achieve effective contact with the nerve fibre as well as involving multiple nerve fascicles over the trunk cross-section, the main purpose of this is spatial selectivity. There is also a reduction in mismatching nerve tissue with artificial material as it isn’t invading the nerve fibre [15].

Virtual Augmented Reality (VAR)
In (Studies 6 [6] and 7 [7]) VAR is a form of therapy for restoring motion and reducing phantom limb pain in patients. There are five components to VAR: (1) the initial input signal from a peripheral or central interface [2]; signal analysis, often using electromyography signals which involves recording the electrical activity produced by skeletal muscles [3]; controls, setting up what movements are going to be assessed and compared [4]; plant, which is the system that translates the electrical signalling into movement and [5] presentation of the intended movement that can be visualised.
Study 6: The inputs were eight bipolar electrode pairs that were placed circumferentially around the residual limb, as well as one ground electrode either below the elbow (in the case of individuals with trans-radial amputation) or below the shoulder (in the case of individuals with trans-humeral amputation). Electromyography signals were digitised via an electrically isolated data acquisition system. Signal analysis algorithms within the VAR performed functions such as: EMG signal filtering, signal feature extraction, and classification using machine learning-based pattern recognition software. The control and plant subsystems translated user-intended movements into commands for individual joints resulting in motion of the entire virtual arm. The system output presentation displayed a rendered 3-D arm within the VAR environment, observed by the user on the visualisation screen. The rendered environment was based on the Musculo-Skeletal Modelling Software allowing for stereoscopic display [6].
Study 7: The inputs were also eight bipolar electrode pairs placed circumferentially around the limb and a ground electrode at the elbow above or below depending on location of amputation (transhumeral or transradial). Signal analysis involved isolating the EMG signals via a data acquisition system. Control subsystem translated user intended movements into low level commands for motor communication, and the plant system allowed for torso movement in the immersive VAR environment which was presented on a visualisation screen [7].
Myoelectric Prosthesis
(Studies 3 [3] and 4 [4]) Both studies used the same methodology, after the patients had undergone comprehensive psychological and physical assessment they took part in daily prosthesis training (PT) for 10 consecutive working days. The training sessions consisted of 3.5 hours with 20 minutes break. Baseline characteristics were assessed before the intervention, before the training session (pre) and after completion of the session (post).
The prosthetic used a somatosensory feedback system on the participants grip strength via the outputs which consisted of eight electrodes inserted into a cuff fixed around the upper arm before the prosthetic fitting. These electrodes transmitted electrocutaneous stimulus patterns to the skin of the patient’s stump. The sessions involved using the prosthesis for manipulating a range of different objects of different materials, the ability to move these objects was assessed on the first and last day of training [4]. Each electrocutaneous stimulation correlates to a grip strength predetermined by the myoelectric prosthesis system [3].
The Outcome measure that is used to compare phantom limb pain is a questionnaire known as the Visual Analogue Scale (VAS). This consists of a straight horizontal line which is 10cm and presented to the patient; the left end of the line [10] defines the ‘worst pain ever’ felt and the right end of the line (0) is ‘absolutely no pain’ felt. The participant is asked to mark the line that represents the severity of phantom limb pain they feel. A ruler is then used to measure to the nearest mm the distance the mark is from 0. No pain is associated with a score of 0-4mm, mild pain is from 5-44mm, moderate pain is from 45-75mm and severe pain is from 75-100mm. This is repeated before and after the intervention.

Information sources: Databases included were PubMed, Web of Science and Scopus.
The first search date for these databases was 11th December 2022 and the last search date was the 14th December 2022. The framework for this Systematic Review is based on the article, ‘The PRISMA 2020 statement: an updated guideline for reporting systematic reviews’ [14].
Electronic searches used for PubMed, Web of Science and Scopus included 4 main searches: ‘Neuroprosthetic AND Phantom Limb Pain’ (28 PubMed, 9 Web of Science, 5 Scopus), ‘Bionic AND Phantom Limb Pain’ (19 PubMed, 12 Web of Science, 12 Scopus), ‘Prosthetic AND Phantom Limb Pain’ (217 PubMed, 250 Web of Science, 204 Scopus), ‘Myoelectric AND Phantom Limb Pain’ (53 PubMed, 72 Web of Science, 71 Scopus).
In total there were 952 papers found via a single reviewer. Duplicates (450 were identified using EndNote and removed, 502 papers were therefore screened of which 409 were excluded as they did not meet the eligibility criterion. The remaining 93 were quality checked for adequate results and methodology. 25 were excluded reasons including not having adequate results on phantom limb pain, such as incomplete VAS scores, only using the VAS score as a eligibility criterion for participation and using other systems such as the Short-form McGill Pain Questionnaire (SF-MPQ) or the Multidimensional Pain Inventory (MPI) and comparing between those scores rather than between VAS scores.
Data extraction
Data was extracted from results tables from all seven of the studies reported in this literature review, and have been summarised into the results tables below (Figures 6 and 7) The descriptions of the interventions were based on the studies that I had come across during this research and had highlighted passages from those studies that outline the key features of the interventions studied.
Results
| Study number | Type of Intervention | VAS (% difference) |
| 1 | TIME | -36.71 |
| 2 | TIME | -37.88 |
| 3 | Prothetic | -15.75 |
| 4 | Prothetic | -7.03 |
| 5 | TIME | -39.47 |
| 6 | VAR | -33.28 |
| 7 | VAR | -17.65 |
All the studies show a percentage decrease in VAS scoring when comparing the pre and post VAS scores. Studies 1, 2 and 5 which involve TIME have the biggest % decrease in VAS scores (-36.71%, -37.88% and -39.47%) The lowest % differences come from Studies 3 and 4 which are both prosthetic interventions (-15.75% and -7.03%). Studies 6 and 7 include the VAR studies which have scores of (-33.28% and -17.65%). The highest score being from study 5 (TIME) with a difference of -39.47% and the lowest score being Study 4 (prosthetic) with a difference of -7.03%.
| Study number | Intervention | Participant number | VAS(pre) | VAS(post) | VAS (% difference) |
| 1 | TIME | 1 | 6.10 | 4.00 | -34.43 |
| 1 | TIME | 2 | 5.90 | 3.60 | -38.98 |
| 2 | TIME | 1 | 5.50 | 3.90 | -29.09 |
| 2 | TIME | 2 | 6.00 | 3.20 | -46.67 |
| 3 | Prosthetic | 1 | 2.80 | – | – |
| 3 | Prosthetic | 2 | 0.66 | – | – |
| 3 | Prosthetic | 3 | 5.10 | – | – |
| 3 | Prosthetic | 4 | 0.00 | – | – |
| 3 | Prosthetic | 5 | 3.05 | – | – |
| 3 | Prosthetic | 6 | 0.39 | – | – |
| 3 | Prosthetic | 7 | 0.21 | – | – |
| 3 | Prosthetic | 8 | 6.60 | – | – |
| 3 | Prosthetic | 9 | 2.06 | – | – |
| 3 | Prosthetic | 10 | 6.39 | – | – |
| 4 | Prosthetic | 1 | – | – | -14.80 |
| 4 | Prosthetic | 2 | – | – | -1.00 |
| 4 | Prosthetic | 3 | – | – | -6.30 |
| 4 | Prosthetic | 4 | – | – | 0.00 |
| 4 | Prosthetic | 5 | – | – | 0.00 |
| 4 | Prosthetic | 6 | – | – | -8.00 |
| 4 | Prosthetic | 7 | – | – | 0.00 |
| 4 | Prosthetic | 8 | – | – | -26.10 |
| 5 | TIME | 1 | 3.80 | 2.30 | -39.47 |
| 6 | VR | 1 | 5.30 | 1.90 | -64.15- |
| 6 | VR | 2 | 3.40 | 2.90 | -14.71 |
| 6 | VR | 3 | 3.05 | 4.75 | +55.74 |
| 6 | VR | 4 | 2.00 | 1.20 | -40.00 |
| 6 | VR | 5 | 1.55 | 1.50 | -3.23 |
| 6 | VR | 6 | 1.45 | 0.75 | -48.28 |
| 6 | VR | 7 | 0.55 | 0.25 | -54.55 |
| 6 | VR | 8 | 3.40 | 0.10 | -97.06 |
| 7 | VR | 1 | 6.80 | 5.60 | -17.65 |
| Study | Intervention | n | Mean VAS % difference | SD | 95% CI | p-value |
| 1 | TIME | 2 | -36.70 | 3.22 | -65.61,-7.80 | 0.039 |
| 2 | TIME | 2 | -37.88 | 12.43 | -149.57,73.81 | 0.145 |
| 5 | TIME | 1 | -39.47 | – | – | – |
| 4 | Prosthetic | 8 | -7.03 | 9.34 | -14.83,0.78 | 0.071 |
| 3 | Prosthetic | 10 | – | – | – | – |
| 6 | VAR/VR | 8 | -33.28 | 46.16 | -71.87,5.31 | 0.081 |
| 7 | VAR/VR | 1 | 17.65 | – | – | – |
| Pooled | TIME (1,2,5) | 5 | -37.73 | 6.52 | –45.82, -29.63 | 0.0002* |
| Pooled | Prosthetic (4) | 8 | -7.03 | 9.34 | -14.83, 0.78 | 0.071 |
| Pooled | VAR/VR (6,7) | 9 | -31.54 | 43.49 | -64.97, 1.89 | 0.061 |
TIME is the only intervention where the improvement is clearly statistically significant, with a narrow CI (SD ≈ 6.5 when pooled) due to the five participants having concise VAS difference scores, with an overall p value of <0.05. VAR/VR’s CI is especially wide (SD ≈ 43.49) due to one participant in Study 6 where their pain worsened (+55.74%), which pulls the interval towards “no effect” or even harm. Studies 5 and 7 each have only one participant, so no variance, CI, or p-value can be calculated at all.
Discussion
Phantom limb pain is a complex and multifactorial condition that has been strongly associated with maladaptive cortical plasticity following limb amputation [16]. This systematic review examined whether neuroprosthetic interventions specifically Transverse Intrafascicular Multichannel Electrodes (TIME), virtual Augmented Reality (VAR) systems, and myoelectric prostheses are associated with reductions in PLP. Across the included studies, the majority of participants demonstrated a reduction in pain severity following intervention, suggesting that neuroprosthetics may play a role in modulating phantom limb pain.
The Visual Analogue Scale (VAS) was selected as the primary outcome measure across all included studies due to its simplicity, ease of administration, and sensitivity to changes in pain intensity. Other pain scales such as the Numeric Rating Scale (NRS-11) were not used due to its controversial assessment of pain, being limited to a ratio of linear properties [18]. These characteristics allow for direct comparison of pain levels before and after intervention and reduce potential miscommunication between clinician and participant. The observed reductions in VAS scores across all neuroprosthetic modalities included in this review indicate a consistent trend towards pain improvement following restoration of sensorimotor engagement. One study looked at the reliability of VAS on acute pain and was found to be reproducible within 9mm by ninety percent [17].
However, the subjective nature of the VAS must be acknowledged as a limitation. Pain perception is influenced by psychological, emotional, and contextual factors, and VAS scores reflect an individual’s experience at a specific moment in time. In studies with longer intervals between pre- and post-intervention assessments, recall bias may have influenced participants’ ability to accurately judge changes in pain severity. Furthermore, the reliance on a single unidimensional pain measure limits insight into functional, emotional, and quality-of-life outcomes associated with PLP.
Differences in the magnitude of pain reduction were observed between intervention types. Studies involving TIME electrodes and VAR-based interventions generally reported larger percentage reductions in VAS scores compared to myoelectric prostheses. This may reflect the importance of restoring bidirectional sensorimotor feedback, which is more directly addressed by invasive peripheral nerve interfaces and immersive virtual environments. These findings support existing theories that reducing the mismatch between motor intention and sensory feedback may attenuate maladaptive cortical reorganisation associated with PLP.
Despite these encouraging findings, the results must be interpreted cautiously. The total sample size across all included studies was small, and most studies employed observational designs without control groups. Additionally, there was considerable heterogeneity in intervention protocols, duration of follow-up, and participant characteristics, limiting the generalisability of the results. The exclusion of randomised controlled trials further restricts the strength of causal inferences that can be drawn from this review.
Several methodological limitations were also identified during the review process. Although studies were screened using PRISMA guidelines, the search strategy could have been further refined by incorporating intervention-specific terminology, which may have identified additional relevant studies. Furthermore, some potentially eligible studies were excluded due to incomplete reporting of pre- or post-intervention VAS scores, highlighting a broader issue of inconsistent outcome reporting within this field while study 3 only provided the average % VAS difference and study 4 also did not provide the individuals pre and post VAS measures
Conclusion
This systematic review suggests that PLP may be partially reversible through neuroprosthetic interventions that restore elements of sensorimotor feedback. Across the included studies, most participants experienced reductions in pain severity following the use of neuroprosthetic systems, particularly those incorporating peripheral nerve interfaces and virtual augmented reality environments.
However, the current evidence base is limited by small sample sizes, heterogeneous intervention types, and a lack of randomised controlled trials. Additionally, the exclusive reliance on subjective pain measures such as the Visual Analogue Scale restricts the ability to capture the multidimensional nature of phantom limb pain.
While these findings highlight the potential role of neuroprosthetics in chronic phantom limb pain management for amputees, further rigorously designed studies with standardised outcome measures and longer follow-up periods are required before firm clinical recommendations can be made.
Overall, while this review demonstrates a consistent trend toward reduced phantom limb pain following neuroprosthetic intervention, the current evidence base remains preliminary. Larger, well-designed longitudinal studies using standardised and multidimensional outcome measures are required to better understand the clinical efficacy, durability of pain reduction, and optimal patient selection for neuroprosthetic-based pain management.
References
- Granata G, Valle G, Di Iorio R, Iodice F, Petrini F M, Strauss I, D’anna E, Iberite F, Lauretti L, Fernandez E, Romanello R, Stieglitz T, Raspopovic S, Calabresi P, Micera S, Rossini P M, (2020). ‘Cortical plasticity after hand prostheses use: Is the hypothesis of deafferented cortex “invasion” always true?’, Clinical Neurophysiology, Volume 131, Issue 10, pages 2341-2348. https://doi.org/10.1016/j.clinph.2020.06.023
- Petrini F M ,Valle G , Strauss I, Granata G, Di Iorio R, D’Anna E, Čvančara P, Mueller M, Carpaneto J, Clemente F, Controzzi M, Bisoni L, Carboni C, Barbaro M, Iodice F, Andreu D, Hiairrassary A, Divoux J, Cipriani C, Guiraud D, Raffo L, Fernandez E, Stieglitz T, Raspopovic S, Rossini P M, Micera S, (2018). ‘Six-Month Assessment of a Hand Prosthesis with Intraneural Tactile Feedback’, Annals of Neurology, Volume 85, issue 1, Pages 137-154. https://doi.org/10.1002/ana.25384
- Preißler S, Thielemann D, Dietrich C, Hofmann G O, Miltner W H R, Weiss T, (2017). ‘Preliminary Evidence for Training-Induced Changes of Morphology and Phantom Limb Pain’, Front Hum Neurosci, Volume 13, Page 211 https://doi.org/10.3389/fnhum.2017.00319
- Dietrich C, Walter-Walsh K, Preißler S, Hofmann G O, Witte O W, Miltner W. H. R, Weiss T, (2011). ‘Sensory feedback prosthesis reduces phantom limb pain: Proof of a principle’, Neuroscience Letters, Volume 507, Issue 2, pages 97-100 https://doi.org/10.1016/j.neulet.2011.10.068
- Di Pino G, Benvenuto A, Tombini M, Cavallo G, Denaro L, Denaro V, Ferreri F, Rossini L Micera S, Guglielmelli E, Rossini P. M. (2012). ‘Overview of the implant of intraneural multi electrodes in humans for controlling a 5-fingered hand prosthesis, delivering sensorial feedback and producing rehabilitative neuroplasticity.’ The Fourth IEEE RAS/EMBS International Conference on Biomedical Robotics and Biomechatronics, Pages 1831-1836 https://doi.org/10.1109/BioRob.2012.6290808
- Perry B. N, Armiger R. S, Wolde M, McFarland K. A, Alphonso A. L, Monson B. T, Pasquina P. F, Tsao J. W (2018) ‘Clinical Trial of the Virtual Integration Environment to Treat Phantom Limb Pain With Upper Extremity Amputation’ Front Neurol, Volume 9, Article 770, Pages 1-9 https://doi.org/10.3389/fneur.2018.00770
- Perry B. N, Alphonso A. L, Tsao J. W, Pasquina P. F, Armiger R. S, Moran C. W. (2013) ‘A Virtual Integrated Environment for phantom limb pain treatment and Modular Prosthetic Limb training’ International Conference on Virtual Rehabilitation (ICVR) https://doi.org/10.1109/ICVR.2013.6662105
- Collinger J. L, Foldes S, Bruns T. M, Wodlinger B, Gaunt R, Weber D. J. (2013) ‘Neuroprosthetic technology for individuals with spinal cord injury’ J. Spinal Cord Med, Volume 36, Issue 4, Pages 258 -272 https://doi.org/10.1179/2045772313Y.0000000128
- Adewole D. O, Serruya M. D, Harris J. P, Burrell J. C, Petrov D, Chen I. H, Wolf J. A, Cullen D. K. (2016) ‘The Evolution of Neuroprosthetic Interface’ Crit Rev Biomed Eng, Volume 44, Issue 2, Pages 123 -152 https://doi.org/10.1615/CritRevBiomedEng.2016017198
- Liberati. A, et al. (2009) ‘The PRISMA statement for reporting systematic reviews and meta-analyses of studies that evaluate health care interventions: explanation and elaboration’ PLoS Med. Volume 6, Issue 7 https://doi.org/10.1371/journal.pmed.1000100
- Stevelink S. A. M, Malcolm E. M, Mason C, Jenkins S, Sundin J, Fear N. T. (2015) ‘The prevalence of mental health disorders in (ex-)military personnel with a physical impairment: a systematic review’ BMJ Open Access, Volume 72, Issue 4, Pages 243 -251 https://doi.org/10.1136/oemed-2014-102207
- Gandhi D. B. C, Sterba A, Khatter H, Pandian J. D (2020) ‘Mirror Therapy in Stroke Rehabilitation: Current Perspectives’ Ther Clin Risk Manag, Volume 16, Pages 75-85 https://doi.org/10.2147/TCRM.S206883
- Gould D, et al. (2001), ‘ Visual Analogue Scale (VAS)’ J Clin Nurs, Volume 10, Pages 697-706 https://doi.org/10.1046/j.1365-2702.2001.00525.x
- Page, M, et al. (2020). ‘The PRISMA 2020 statement an updated guideline for reporting systematic reviews’ BMJ 2021;372:n71 https://doi.org/10.1136/bmj.n71
- Boretius T, Yoshida K, Badia J, Harreby K, Kundu A, Navarro X, Jensen W, Stieglitz T, (2012). ‘A Transverse Intrafascicular Multichannel Electrode (TIME) to Treat Phantom Limb Pain – Towards Human Clinical Trials’ Biosens Bioelectron, Volume 26, Issue 1, Pages 62-69
- Duarte, D, et al. (2020). ‘Cortical Plasticity in Phantom Limb Pain: a fMRI study on the neural correlates of behavioural clinical manifestations’ Pychiatry Res Neuroimaging, https://doi.org/10.1016/j.pscychresns.2020.111151
- Polly, E, et al (2008). ‘Reliability of the Visual Analog Scale for Measurement of Acute Pain’ Academic Emergency Medicine, Volume 8, Issue 12, Pages 1153-1157 https://doi.org/10.1111/j.1553-2712.2001.tb01132.x
- Craig T, et al. (2003). ‘The Numeric Rating Scale for Clinical Pain Measurement: A Ratio Measure?’ Pain Practice, Volume 3, Issue 4, Pages 310-316 https://doi.org/10.1111/j.1530-7085.2003.03034.x